Biogas generator set requirements for biogas:
Within 1 meter from gas intake valve of generator set
1) Gas temperature ≤ 40ºC
2) Pressure 3-20kpa, pressure changing rate ≤ 1kpa/min
3) H2S ≤ 200mg/Nm3
4) NH3 ≤ 20mg/Nm3
5) CH4 content ≥ 40%, changing rage ≤ 2%/min
6) Impurity particle size ≤ 5μm, impurity content ≤ 30mg/Nm3
7) Moisture content ≤ 40g/Nm3
Model Number (Engine Type) | LHBG140 |
Brand Name | LVHUAN |
Prime Power/Standby Power | 112KW/140KW |
Rated Speed | 1500/1800RPM |
Rated Frequency | 50/60Hz |
Rated Voltage | 400V/230V |
Phase | AC 3-Phase, 4 wire |
Voltage Stability | ≤±2% |
Voltage transient | ≤±10% |
Voltage Stable time | ≤1s |
Heat consumption | ≤11mj/kw.h |
Lubricant consumption | ≤1.0g/kw.h |
Engine Capacity | 25.80 L |
Cylinder Number | 12 |
Cylinder Bore | 135mm |
Stroke | 150mm |
Starting System | DC 24V electric motor |
Cooling method | water cooler |
Lubricant method | Passive and flying lubricant |
Isolation class | H |
Protection | IP23 |
Alternator | Chinese Siemens |
Power Factor | 0.8 lagging |
Exciting method | brushless |
Colour | your choice |
Certificates | ISO 9001:2008, CE |
Warranty | 1 year or 1000 running hours which arrives first |
Type | Open |
Control system | Automatic alarm system |
Size | 3200x1350x1750mm |
Weight | 2900kg |