Description:
This generator uses gas as power. The gas will burn directly in the engine cylinder and then provide mechanical force to the alternator to generate electricity. A generator set mainly consists of 3 parts: gas engine, alternator and radiator. The electricity generated can be connected to the national grid or used for daily use and industrial purposes.
Unit requirements for biogas
Within 1m of the gas inlet valve of the gas unit
1. Biogas temperature ≤ 40ºC;
2. Biogas pressure 3~20kpa, pressure change rate ≤ 1kpa/min;
3. H2S ≤ 200mg/Nm3
4. NH3 ≤ 20mg/Nm3
5. CH4 content in biogas ≥ 40%, change rate ≤ 2%/min;
6. Impurity particle size ≤ 5μm, impurity content ≤ 30mg/Nm3;
7. Moisture content in biogas ≤ 40g/Nm3;
Product Parameters
Brand Name |
LVHUAN |
Rated Voltage |
400V/230V |
Rated Frequency |
50Hz |
Rated Speed |
1500r/min,1000r/min |
Phase |
AC 3-Phase, 4 wire |
Power Factor |
0.8 |
Voltage Steady State |
≤±2% |
Voltage Transient State |
≤±10% |
Voltage Settling |
≤1s |
Voltage Volatility |
≤±0.5% |
Frequency Steady State Regulation Rate |
≤0.5% |
Frequency Transient State Regulation Rate |
≤±10% |
Heat Consumption |
≤11.38mj/kw.h |
Pressure |
3-20kpa |
Intake Mode |
Natural intake |
Sparking Mode |
Sparking pl |
Voltage Regulation Mode |
Automatic |
Speed Regulation Mode |
Electronic speed regulate |
Lubricating Mode |
Pressure and splash |
Cooling Mode |
Circulating water cooling |
Starting Mode |
24V electric motor |
Overhaul Time |
≥30000h |
Colour |
According to your request |
Noise |
≤105db(A) |
Exhaust Temperature |
≤650ºC |
Warranty |
1 year or 1000 running hours arrives first |
Construction of power plants
- The generator room is generally open or semi-open, and the floor should be easy to clean and not easy to generate sparks.
- If a closed generator room is required, a single-story building must be built, and all doors and windows must be opened outward. Please install a large-capacity exhaust device to prevent gas accumulation.
- The generator room and the operating room must be separated and must not be directly connected. The observation window should be double-glazed and protected by a wire mesh.
- Lightning arresters must be installed.
- Equipped with sufficient fire-fighting equipment.
- The "NO FIRE" sign should be obvious, and open flames are strictly prohibited in the machine room.
- The exhaust contains flammable gases, so the exhaust pipe of the generator must be led to the outdoors and the exhaust pipe must be tightly connected.
Service
Service
1. Pre-sales service:
(1) We will send engineers to explore the site of the power station free of charge.
(2)According to the site conditions, we will provide design drawings such as power plant floor plan, cooling system diagram, generator set foundation, control room design, etc.
2. In-sales service:
(1)Operator training will be conducted by our technicians during the commissioning process or in factory training courses in China.
(2)Our technicians will go to the site to guide and assist in completing the installation and commissioning of the generator set.
3. After-sales service:
(1)We have a strong after-sales team, we will respond within 24 hours and provide technical support by phone or on-site guidance to help our customers get the most profit.
(2)For quality issues, we will provide you with free service during the warranty period.
(3)We provide one-year warranty and lifetime service.
We provide overseas installation, repair and maintenance services. If necessary, we provide online guidance services at any time. Our pre-sales, in-sales and after-sales services are trustworthy, so you can rest assured.
Product picture
Warranty:
One year. During this year, we provide all accessories for free. After this period, the accessories are no longer free. In addition, we will ship one set of accessories with the generator set for free.