Long life span industrial exhaust gas electric generator set
CORE FEATURES
· Low cost in maintenance.
· Large cylinder, Long Stroke, Low Speed, which means big reserve power capacity
and constant power output.
· Low Engine Speed at 500 or 600RPM.
· Naturally Aspirated, which means low failure rate and minimal downtime.
· Internal Mixing System (for high hydrogengas)
· Strong Treatment and Resistance ability against TAR.
· Long Overhaul Time of 60000 hours and lifecycle of 20-25 years.
· CE and ISO approved.
· Product range: Syngas generator, biogas generator, natural gas generator, biomass generator, wood gas generator,coal gas generator, coal bed gas generator, syngas generator,diesel generator etc.
Technical Parameters |
|||
Model Number |
LH400GFJ |
LH500GFJ |
LH600GFJ |
Brand Name |
LVHUAN |
||
Engine Type |
6300D/J-1 |
8300D/J-2 |
8300D/J-3 |
Rated Power |
400KW |
500KW |
600KW |
Rated Speed |
600 |
||
Rated Frequency |
50/60Hz |
||
Rated Voltage |
400/230V |
||
Phase |
3 phase, 4 wire |
||
Voltage Stability |
±2.5 |
||
Voltage Transient |
±15 |
||
Voltage Stable time |
≤1.5S |
||
Heat consumption |
≤12MJ/kw.h |
||
Lubricant consumption |
≤1.0g/kw.h |
||
Engine Capacity |
161 |
215 |
215 |
Cylinder Number |
6 |
8 |
8 |
Cylinder Bore |
300mm |
||
Stroke |
380mm |
||
Starting System |
Compressed air/motor start |
||
Cooling Method |
water cooled |
||
Lubricant Method |
Passive and flying lubricant |
||
Isolation Class |
H |
||
Protection |
IP23 |
||
Alternator |
jiali/ganfaneng |
||
Power Factor |
0.8 lagging |
||
Exciting Method |
phase compound excitation/self-excitation |
||
Colour |
your choice |
||
Certificates |
ISO 9001:2008 |
||
Warranty |
1 year or 1500 running hours |
||
Type |
Open |
||
Control system |
Automatic alarm system |
WORKING CONDITION
Worksite Requirement
The worksite needs to meet following basic requirements:
a) Ambient temperature between -20ºC~+40ºC;
b) Relative humidity less than 90%(20ºC);
c) Site elevation not higher than 2000m;
d) For outdoor installation, simple rain shelter is required.
Gas Requirements
Within 1m to the intake valve of gas generator set:
1) Gas temperature≤40ºC;
2) Gas Pressure: 2.5~10kPa, Pressure changing rate≤ 1kPa/min;
3) H2S≤200mg/Nm3;
5) Tar Content≤20mg/Nm3;
6) Moisture Content ≤20g/Nm3;
7) Impurity particle size≤5μm; impurity content≤30mg/Nm3;
8) Heat value≥4MJ/Nm3;