50 Kw Natural Gas Generators Prices with Turbine Engine

Product Details
Customization: Available
After-sales Service: One Year
Warranty: One Year

360° Virtual Tour

Diamond Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
81
Year of Establishment
2008-10-13
  • 50 Kw Natural Gas Generators Prices with Turbine Engine
  • 50 Kw Natural Gas Generators Prices with Turbine Engine
  • 50 Kw Natural Gas Generators Prices with Turbine Engine
  • 50 Kw Natural Gas Generators Prices with Turbine Engine
  • 50 Kw Natural Gas Generators Prices with Turbine Engine
  • 50 Kw Natural Gas Generators Prices with Turbine Engine
Find Similar Products
  • Overview
  • Detailed Photos
Overview

Basic Info.

Model NO.
LHNG50
Gas Source
Natural Gas
Certification
CE, TLC, ISO, CCC
Power
10 Kw--1000 Kw
Standard
Standard
Generator Set Alternator
Siemens
Generator Output Power
400kw
Ignition System
Sparking Plug
Starting System
DC 24V Electric Motor
Isolation Class
H
Heat Consumption
Less Than 11.8mj/Kw.H
Engine Capacity
6.49L
Generator Set Fuel
Natural Gas or LNG
Rated Voltage
400V/230V
Rated Frequency
50/60Hz
Transport Package
Exporting Standard Packing
Specification
2300x1000x1480mm
Trademark
Shandong Lvhuan
Origin
Shandong, China
HS Code
8502200000
Production Capacity
1000

Product Description

500 kw Natural Gas Generators Prices with Turbine Engine
 
Product Pictures of Gas Generators


 
Technical Parameters for 50kw Natural Gas Generator
Model Number (Engine Type) LHNG50
Brand Name LVHUAN
Prime Power/Standby Power 40KW/50KW
Rated Speed 1500/1800RPM
Rated Frequency 50/60Hz 
Rated Voltage 400V/230V 
Phase AC 3-Phase, 4 wire
Voltage Stability ≤±2%
Voltage transient ≤±10%
Voltage Stable time ≤1s
Heat consumption ≤11mj/kw.h
Lubricant consumption ≤1.0g/kw.h
Engine Capacity 6.49L
Cylinder Number 6
Cylinder Bore 105mm
Stroke 125mm
Starting System DC 24V electric motor
Cooling method water cooler
Lubricant method Passive and flying lubricant
Isolation class H
Protection IP23
Power Factor 0.8 lagging 
Exciting method Brushless 
Colour According to your request
Certification ISO 9001:2008, CE
Warranty 1 year or 1000 running hours arrives first
Type Open 
Control system Automatic alarm system 
Size 2300x1000x1480mm
Weight 1350kg

-------------Gas requirements for generator

1m from genset's pressure regulating valve of inlet
1. Pressure of natural gas: 80~200kPa
2. CH4 content of natural gas≥70%
3. H2S≤20mg/Nm3
4. Impurities particle size≤5μm, impurity content≤30mg/Nm3
Purification of natural gas has a significant impact on machine life and continuous running time!

---------------Our Advantages

1. Covering more than 40,000 square meters.
2. Among 260 employees, more than 100 are practiced technicians.
3. One year guarantee period and lifetime service.



-------------Our Perfect Service

1. Pre-sale service: 

1) We will send our engineer to prospect the site of power station free of charge.
2) According to the situation of site, we will provide design drawings, such as power plant floor drawing, cooling system drawing, genset foundation, control room design, etc.
 
2. Sale service:
1) Operator training would be conducted by Lvhuan technicians during the process of commissioning or Factory training course in China,
2) Installation and commission of the genset would be instructed assisted by Lvhuan technicians at site.
 
3. After-sale service:
1) We have strong after-sale team, we will response within 24 hours and provide technical supports by phone or site guiding, help our clients to gain the biggeset profit.
2) For the quality problem, we will service for you free of charge during the guarantee period.
3) We  provide one year guarantee period and lifetime service.

----------------Our Customers

With professional and honest, we have established many business relationships with companies in Congo,  Italy, Turkey, Vietnam, Thailand, Japan...Here are some pictures.



------------------------ Company Profile

Δ   Established in 2008

Δ   Factory area over 40000 square meters

Δ   Over 260 employees, technicians over 100 people

Δ   Provide repaire  service free during the guarantee period

Δ   Got the CE, ISO14001, ISO9001 certification

Δ   Website lvhuanpower.en.made-in-china.com

----------------------------FAQ

√    HOW TO CHOOSE THE RIGHT MODEL?

      1. It depends on prime power, voltage,frequency and fuel type.

          PLEASE TELL ME WHAT FUEL (NATURAL GAS, BIOGAS, BIOMASS GAS, WOOD SYNGAS, METHANE,      COAL GAS) OR RAW MATERIAL (LIKE WOOD, GRASS, NUTSHELL ETC). 

       2. Our salesman and engineers are always available at your service.

√     WHAT IS THE OIL CONSUMPTION AND CAPACITY PER HOUR?

       1.    1.0---1.63 g of lubricant oil consmption per hour.

               1.0 cubic meter gas can produce 1.5-3.0 kw/h power.

√    WHAT THE OVERHAUL?
   
      About   30,000 working hours. One week is enough to finish. We offer manual for weekly, monthly and overhaul maintenance.

√   WHAT IS THE WARRANTY?

      One year. We offer all spare parts FREE of charge during warranty period. After this period, spare parts are not free. What's more, a set of spare parts will be shipped together with generator set free of charge.

√    HOW TO MAKE AN ORDER?

      Just send inquiry / message to our sales. And we will reply and offer the details as soon as possible according to your request.

Professional Packing and Loading Team for Gas Generator

Notice About Power Plant Construction 
 
×   Generator Room is usually constructed in open or semi-open type. The floor should be easily to clean and not easily to spark.

×   If you want to construct Closed Generator Room, you must construct a single storey building. The open direction of all the doors and windows must turn outside. Please install some big capacity displacement device to      avoid gas gathering.

×  Generator Room and the Operation  Room must be separated, can not be directly connected. The observation window should be with double deck glass protected by steel wire mesh.

×   Lightning arrester is necessary.

×   Prepar enough fire extinguishing appliances.

×   "NO FIRE" mark should be obvious, open flame in the generator room is not allowed.

×    In the exhaust gas, there are combustible gas. So, the exhaust pipe of the generator must be leaded to outside of room. The exhaust pipe must be connected tightly.
Showcase for Gas Generators
 
Detailed Photos

50 Kw Natural Gas Generators Prices with Turbine Engine50 Kw Natural Gas Generators Prices with Turbine Engine50 Kw Natural Gas Generators Prices with Turbine Engine50 Kw Natural Gas Generators Prices with Turbine Engine

50 Kw Natural Gas Generators Prices with Turbine Engine

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier